Find usg product specific cad and revit files.
2 hr rated roof assembly.
All new fire rated roof ceiling assembly files.
2 hour exterior wall assembly ul design no.
These listings are short summaries to serve as a.
3 4 fr 83 12 x 12 z runners fluorescent type none 2 1 2 concrete.
Urb concealed grid system and tile.
Wood joists wood i joists floor trusses and flat or pitched roof trusses spaced a maximum 24 o c.
1 2 12 7 mm toughrock fireguard c or 1 2 12 7 mm densarmor plus fireguard c gypsum panel applied perpendicular to resilient channels 24 610 mm o c.
Gypsum panel end joints located midway between continuous channels and attached to additional pieces of channels 54 1372 mm long with screws 12 305 mm o c.
These wall assembly files are used for planning and estimation purposes for many ul wall types such as fire rated wall assemblies.
Shaft wall limiting heights spans.
Stc description system rating test no.
Our cad and revit library of design drawings of wall intersections joints and other construction details.
Fire rated construction acoustical performance partition applications fire detail physical data description test no.
Ibc table 721 3 item 21 1 1 describes a single prescriptive 1 hour rated floor or roof assembly that includes wood trusses.
With 1 2 wood structural panels with.
Concrete with cellular steel 3 hr.
Usg provides resources here for our ul wall assemblies for seamless integration into any construction project.
276 fire rated ceiling assemblies suspension ceiling designs floor ceiling designs a003 3 hr.
Gypsum wallboard roof ceilings wood framing pitched roof truss 11 1 hr.
Wd stud 2 layers 5 8 sheetrock brand gypsum n a j panels firecode core outside both sides 5 8 sheetrock brand gypsum panels firecode core inside both sides 2 rows 2 x 4 24 o c base layer.
Fire rated wall floor and ceiling assemblies provide the necessary fire and smoke barriers to create compartmentalization during a fire safeguarding against the spread of fire and smoke within a building or to and from a building.
Screw fastened perpendicular to lower chord of wood trusses of 2 x 4 38 mm x 89 mm.
Ul p533 roof ceiling one layer 5 8 15 9 mm fire shield c ga rc 2603 wallboard attached to 1 2 12 7 mm resilient furring channel spaced 12 o c.
These assemblies need to meet fire and smoke safety and environmental sustainability requirements.
12 x 24 2 x 4 8 w10 x 25 beam floor units and beam support 3 hr.
6 usg fire resistant assemblies test certiļ¬cation test conditions and fire and sound tested assemblies listed in this selector are based on characteristics properties and performance certificationof materials and systems obtained under controlled test conditions as set forth in the appropriate astm standard in effect at the time of test.